Palo Verde provides the following response:

1)     RP does not provide constant coverage on the refuel bridge during fuel 
moves
2)     We currently use the Eberline EC-4; however, this will soon be replaced 
with a Miron Technologies DRM-2 with local and telemetric monitoring 
capabilities.  We have several telemetric ARMs around the refuel pool deck to 
monitor dose rates during fuel, Rx Head, and Upper Guide structure movements.

Seth

From: [email protected] [mailto:[email protected]] On Behalf Of 
[email protected]
Sent: Tuesday, May 31, 2011 7:56 AM
To: [email protected]
Cc: [email protected]
Subject: Powernet: RP Coverage During Fuel Moves

All,

I have a couple questions concerning RP coverage during fuel moves


3)     During fuel moves do you provide constant RP coverage on the refuel 
bridge?
4)     Do you use any form of remote monitoring devices on the refuel bridge?


Harry Miller
Radiological Engineer
Exelon Generation
Braidwood Station
815-417-2713
[email protected]<mailto:[email protected]>



************************************************** This e-mail and any of its 
attachments may contain Exelon Corporation proprietary information, which is 
privileged, confidential, or subject to copyright belonging to the Exelon 
Corporation family of Companies. This e-mail is intended solely for the use of 
the individual or entity to which it is addressed. If you are not the intended 
recipient of this e-mail, you are hereby notified that any dissemination, 
distribution, copying, or action taken in relation to the contents of and 
attachments to this e-mail is strictly prohibited and may be unlawful. If you 
have received this e-mail in error, please notify the sender immediately and 
permanently delete the original and any copy of this e-mail and any printout. 
Thank You. **************************************************
--- NOTICE ---

This message is for the designated recipient only and may contain confidential, 
privileged or proprietary information.  If you have received it in error, 
please notify the sender immediately and delete the original and any copy or 
printout.  Unintended recipients are prohibited from making any other use of 
this e-mail.  Although we have taken reasonable precautions to ensure no 
viruses are present in this e-mail, we accept no liability for any loss or 
damage arising from the use of this e-mail or attachments, or for any delay or 
errors or omissions in the contents which result from e-mail transmission.

Reply via email to