North Anna's response: 1. No frisking required. Traveling from one RCA to an adjacent RCA.
2. A whole body frisk prior to exit. 3. The majority of times a whole body frisk prior to exit. If background levels do not allow (> 200 cpm) then guidance is provided to the worker for a hands & foot frisk and to proceed to the nearest monitoring station. 4. Previously yes. We now require a whole body frisk prior to exit unless background levels do not allow. Barbara Thompson Supervisor of Exposure Control Dominion - North Anna Power Station Email: [email protected]<mailto:[email protected]> Phone: 540-894-2605 Beeper: #3469 From: [email protected] [mailto:[email protected]] On Behalf Of Thomson, Raymond W. Sent: Thursday, June 30, 2011 4:14 AM To: '[email protected]' Subject: Powernet: Bench Marking Questions Columbia Generating Station would like to benchmark the industry on Radiological Controlled Areas (RCA), exit practices outside of established RCA exit points. Areas such as exits through doorways, rollup doors, hatch to outside RCA, e.g. rooftops, or satellite RCA. Your response or comments to the following questions are greatly appreciated. 1. When exiting the RCA from inside the power block to an RCA outside the power block which is exposed to the environment, do you require? * A whole body frisk prior to exit. * Hand and foot frisk. * No frisking required. * Other, please provide a brief summary. 1. When exiting the RCA to a non-RCA through doorways, rollup doors or truck bays what are your personnel frisking requirements? * A whole body frisk prior to exit. * A whole body frisk prior to exit and proceed to the nearest Whole Body contamination monitor. * Hand and foot frisk prior to exit and proceed to the nearest Whole Body contamination monitor. * Other, please provide a brief summary. 1. When exiting satellite RCA's which are established outside the main RCA and are exposed to the environmental elements what are your personnel frisking requirements? * A whole body frisk prior to exit. * A whole body frisk prior to exit and proceed to the nearest Whole Body contamination monitor. * Hand and foot frisk prior to exit and proceed to the nearest Whole Body contamination monitor. * Exit the area and proceed to nearest Whole Body contamination monitor. * Other, please provide a brief summary. 4. Does your facility have any satellite RCA's which do not require personnel to complete a whole body or hand and foot frisk upon exit? Ray Thomson Health Physics Staff Advisor Columbia Generating Station [email protected] 509-377-8273 CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.