Fermi - same practice as Columbia, no tethers Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected]
From: "Thomson, Raymond W." <[email protected]> To: "[email protected]" <[email protected]> Date: 04/10/2012 06:43 PM Subject: Powernet: RE: BWR LPRMs Sent by: [email protected] Columbia’s Response: 1. Do you tether LPRMs to the side of the SFP handrails? No, they are bent and placed on hangers in SFP until they are disposed of. 2. If so, do you lock them to prevent inadvertent removal? No stored underwater, no tether. 3. If so, do you consider them VHRAs or LHRAs? N/A From: [email protected] [mailto:[email protected]] On Behalf Of Barnhill, Carlette Sent: Tuesday, April 10, 2012 11:07 AM To: '[email protected]' Subject: Powernet: BWR LPRMs Progress Energy’s Brunswick site would like information on the following: How do you handle storing, locking and tagging old LPRMs that are removed from the core? 1. Do you tether LPRMs to the side of the SFP handrails? 2. If so, do you lock them to prevent inadvertent removal? 3. If so, do you consider them VHRAs or LHRAs? We tether our LPRMs, lock and tag them but we do not use a VHRA key to lock. Thank you for your time and please respond to: Terri Tuck [email protected] PGN Brunswick Nuclear Site Southport NC