Fort Calhoun does them weekly. We have a documented analysis supporting our
reasoning. Basically, the equipment we have checks itself quite often and will
take itself out of service if there is a problem. We tested that as part of
the analysis.
David Brehm
Radiological Engineer
Office: 402.533.7582
Radiation Protection - Nuclear Operations
Cellular: 402.214.0107
Omaha Public Power District - Fort Calhoun Nuclear Station
Pager: 402.561.3310
9610 Power Lane, Blair, NE 68008
[email protected]
From: [email protected] [mailto:[email protected]] On Behalf Of
Byrum, William F
Sent: Tuesday, July 03, 2012 9:43 AM
To: [email protected]
Subject: Powernet: Exit Personnel Contamination Monitor Source Check Frequency
(ONE MORE TIME)
Duke Energy request the following information:
What the frequency of source response checks for final release / exit monitors
(specifically beta, not gamma portals)? Daily all detectors, daily some
detectors, weekly, etc. ?
You may respond via Powernet or to directly to me at the email below.
Bill Byrum, CHP,RSO
EnRad Laboratories
Duke Energy
[email protected]<mailto:[email protected]>
Phone 980.875.5811
----------------------------------------------------------------------
This e-mail contains Omaha Public Power District's confidential and proprietary
information and is for use only by the intended recipient. Unless explicitly
stated otherwise, this e-mail is not a contract offer, amendment, or
acceptance. If you are not the intended recipient you are notified that
disclosing, copying, distributing or taking any action in reliance on the
contents of this information is strictly prohibited.