Fermi NE / Thermo IPM9D (Argos5AB coming, looking at having a min count time of between 6-8 sec / side to achieve desired actual performance)
IPM9D set for min 10 sec count time / per side (when plant at full power, count time is between 11-15 secs / side) No INPO issues with current process (meaning smear performance test completed sat, near 100% alarm rate) Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected] From: [email protected] To: [email protected] Date: 08/31/2012 01:19 PM Subject: Powernet: Quick Survey on "Beta Booths" Sent by: [email protected] 1. What make/model of RCA personnel beta exit monitor do you use? 2. What is your typical count time per side? 3. Any recent INPO hits on your current process? Roger Schanzenbach HP Technical Support San Onofre Nuclear Generating Station (SONGS) (949) 368-9580 ----------------------------------- Powernet - a service of the Health Physics Society Power Reactor Section Powernet archives at http://www.mail-archive.com/[email protected]/ Reply to: [email protected] If Questions, contact Mike Russell, CHP at [email protected]