For high activity smears Columbia does not put >50k cpm in our bench counter.  
We have a smear holder Ludlum 43-5 alpha scintillation detector and a Ludlum 
Model 3 with scaler feature to do timed smear counts and count the smears right 
at the location.

From: [email protected] [mailto:[email protected]] On Behalf Of 
Barnby, Monica
Sent: Monday, October 01, 2012 7:52 AM
To: '[email protected]'
Subject: Powernet: Alpha ratio for high activity smears


Hello,
Which instruments do you use for counting high activity smears (> 50,000cpm) to 
determine beta-gamma/alpha ratios?
At Diablo, we are currently using the BC-4 and SAC-4.
Monica Barnby


________________________________
PG&E is committed to protecting our customers' privacy.