Columbia Generating Station has the same practice as River Bend.
Ray Thomson Health Physics Craft Supervisor Columbia Generating Station [email protected] Office, 509-377-8273 From: [email protected] [mailto:[email protected]] On Behalf Of Soileau, Jessica Sent: Tuesday, July 16, 2013 7:22 AM To: [email protected] Subject: RE: Powernet: DLR / TLD practices River Bend Nuclear Station Response Below Fermi 2 will be installing hand geometry this year and will allow security keycards to go home. We currently store our DLRs on security key cards and would appreciate your input on the below questions: 1) What type of DLR (TLD, OSL, Film) do you use? OSLD 2) Does your site take DLRs home? Yes. 3) If no, how/where do you store them on site? Only control stored on site. 4) If yes, do you use control dosimetry from on-site, off-site, or both to subtract background radiation? On-site Control badges stored outside of the PA in dosimetry office. No offsite controls. 5) How do you do DLR exchange and how long does it take you? We change them out semi annually Jan. 1st and July 1st. We always have a few that take a week or so to change out. We lock the old badges out of the RCA, so it helps with quick return for most. 6) Any other pros/cons of taking DLRs home vs staying on site? Taking DLR's home is common practice in many applications of dosimetry. This is also widely practiced in the medical profession (hospitals, radiology,etc.) and is accepted practice with regulatory agencies. It also is very appropriate if you consider Emerg. Response Activities and Radworkers that would need to report to various locations during an event, i.e. they would have their DLR's on the way in to the plant; otherwise, if stored onsite, access to them may be an issue in a real event. Jessica Soileau Sr. Health Physicist/Chemical Specialist Dosimetry, Instruments and Shipping River Bend Nuclear Station 225-336-6494 Please respond to Powernet or Jim Stewart directly, [email protected]<mailto:[email protected]> (734.586.1388) Thanks, Benjy Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected]<mailto:[email protected]> CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.