Ginna is experiencing elevated containment airborne tritium (1.77 E-5 uCi/ml - 0.9 DAC, historical cycle peaks 3E-7 to 5E-6) with no apparent source of Reactor Coolant leakage (containment radiogas is not elevated as would be expected with RCS leakage).
Benchmark Questions: What is your containment airborne tritium concentration? Type of plant? (Ginna is 2-loop Westinghouse PWR) Have you experienced elevated tritium airborne in containment and what was the probable cause? Have you ever implemented urinalysis for containment entries due to tritium exposure? Thanks, Stephen Holmes Sr. Plant Health Physicist CENG - RE Ginna NPP [email protected]<mailto:[email protected]> 585-771-3577 This e-mail and any attachments are confidential, may contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. -EXCIP