Fermi
1. Do you monitor your slings and harnesses in a SAM if they’ve
been used in the RCA?
yes
2. If so, is there a set activity or alarm level below which
the sling/harness may be used in a clean area? Or is it go/no-go for
clean area use based on any alarm?
go / no go, if item alarms SAM, it's classified as contaminated
Benjy Bertossi
Fermi2 - RP Supervisor
734-586-4935
[email protected]
From: "Sumrall, Matthew" <[email protected]>
To: "[email protected]" <[email protected]>
Date: 03/25/2014 06:37 PM
Subject: Powernet: Slings and Harnesses
Sent by: [email protected]
I realize similar questions to this have been asked in various forms over
the years, but I don’t see any specific answer to what we’re looking for:
1. Do you monitor your slings and harnesses in a SAM if they’ve
been used in the RCA?
2. If so, is there a set activity or alarm level below which
the sling/harness may be used in a clean area? Or is it go/no-go for
clean area use based on any alarm?
Thanks!
Matt Sumrall
Sr. Health Physicist
STP Nuclear Operating Co.
[email protected]
(361) 972-4597
<<inline: graycol.gif>>