Columbia,

Yes still using the ASP-1/NRD probe.

In addition to what Fred was saying - another big factor is gamma rejection.  
Basically, there is no meter indication in gamma fields up to 1 rem/hr (and 
probably even higher).  Where as many of the other lighter neutron meters have 
problems when any gamma fields are present and with our plant typically where 
we have neutrons (e.g., Drywell) we would also have high gamma fields up to 
200-500 mrem/hr.



Michael Kinmark

Columbia Generating Station

Reply via email to