From: [email protected] [mailto:[email protected]] On Behalf Of Benjy P Bertossi Sent: Monday, March 02, 2015 12:11 PM To: [email protected] Cc: Bruce D Rumans Subject: Powernet: HEPA DOP testing
What general requirement does your site have for testing portable HEPA units used for radiological controls? All portable HEPA inside the RCA require annual integrity testing. We use the ATI aerosol photometer and aerosol generator with PAO (poly alpha olefin). What is frequency for DOP testing portable HEPA units / vacuums? Annual, after HEPA filter replacement, prior to use for new units, and if system integrity is suspect. Is there a difference for DOP testing requirements for portable HEPA used for asbestos work? No, the testing requirement is the same for all portable HEPA units/vacuums used in the RCA. Thanks, Benjy Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected]<mailto:[email protected]> PG&E is committed to protecting our customers' privacy. To learn more, please visit http://www.pge.com/about/company/privacy/customer/