Hello, This is DEME related question.
How does the function SetCDUpdateFreq affect the maximum bin allowance? I have been running a code with SetCDUpdateFreq(6) and everything was working fine. However, when I changed the input from 6 to 15, I started getting an error saying that Bin 32 contains 264 triangular mesh facets, exceeding maximum allowance (256). Also, I am running a cone penetration test, does a value of 6 considered a low value for such a test? Thank you so much in advance, -- You received this message because you are subscribed to the Google Groups "ProjectChrono" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/projectchrono/3155fa77-7f1f-4ef0-9dea-97241175e89en%40googlegroups.com.