Hello,

I am implementing a simple test of a cylinder with fixed extremities under 
pressure (length of 42 mm, radius of 2.5 mm and thickness of 0.6 mm). 
Material has a Young's modulus of 0.6 MPa and nu=0.45.
I tested ShellBST, ShellReissner and ShellANCF4234 in chrono and compared 
the results with Abaqus.

With a pressure of 0.001 MPa, the results are the same as Abaqus. However, 
when increasing the pressure to 0.03 MPa, the deformation of the cylinder 
is roughly twice lower in chrono than in Abaqus (results are in the same 
magnitude for all 3 shell elements).

To completed the analysis, in Abaqus, when setting the NLGEOM parameter to 
NO, the deformation goes down to the range of chrono deformation.

My question then : are there shelle elements able to consider large 
deformations ? Did I forget a hidden parameter somewhere ?

Thanks a lot for you help,
Solenne

-- 