On 02/06/2021 00:01, Naveen Badam wrote:
Thanks Stuart.

That would be the obvious thing to do.

Is there any way we can manage the memory segment size limits? I believe below err represents the issue loading specific segment or it exhaust after loading x number of segment since it exceeded the memory limit?

Memory usage is controlled via the number of time series being scraped and the queries performed (there are a couple of settings to reject large queries), so in this case you could reduce the number of targets or use the configuration to reject some of the metrics.

--
Stuart Clark

--
You received this message because you are subscribed to the Google Groups 
"Prometheus Users" group.