I have a new device that reports its SNMP values as hex byte strings
encoded using IEEE-754.
For example the value "423ce042" means 47.219.

This was proposed as a textual convention in RFC6340 but it’s the first
time I’ve come across it.
https://www.rfc-editor.org/rfc/rfc6340

As far as I can tell, snmp-exporter cannot decode this format. Would this
be a worthwhile feature to add, or would I be better off writing a custom
exporter for this device?

If you’re curious, the device is a cinema calibration tool from HSG Labs.
https://hsg-labs.com/ultimate.html

-- 