https://issues.apache.org/jira/browse/PROTON-109?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13689425#comment-13689425
]
Ken Giusti commented on PROTON-109:
-----------------------------------
Review board for proton-c patch:
https://reviews.apache.org/r/12011/
> Proton should handle inbound max-frame size violations.
> -------------------------------------------------------
>
> Key: PROTON-109
> URL: https://issues.apache.org/jira/browse/PROTON-109
> Project: Qpid Proton
> Issue Type: Bug
> Components: proton-c, proton-j
> Reporter: Ken Giusti
> Assignee: Ken Giusti
> Fix For: 0.5
>
>
> According to the spec, if the local proton-c client has configured a maximum
> frame size, and the remote attempts to send a frame that violates that size:
> A peer that receives an oversized frame MUST close the Connection with the
> framing-error error-code.
> Need to verify this behavior is handled.
--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators
For more information on JIRA, see: http://www.atlassian.com/software/jira