https://bugs.freedesktop.org/show_bug.cgi?id=106579
Bug ID: 106579
Summary: RAOP2 sets volume to 100% when connecting
Product: PulseAudio
Version: unspecified
Hardware: x86-64 (AMD64)
OS: Linux (All)
Status: NEW
Severity: normal
Priority: medium
Component: modules
Assignee: pulseaudio-bugs@lists.freedesktop.org
Reporter: f...@felinira.net
QA Contact: pulseaudio-bugs@lists.freedesktop.org
CC: lenn...@poettering.net
Connecting to a RAOP2 (AirPlay) device sets its volume to 100% on connect, even
when the sink volume is configured differently.
Steps to reproduce:
1. Play audio via a RAOP2 sink
2. Set the sink device volume to eg 30% via pavucontrol.
3. The Audio Device correctly changes the volume to 30%
4. Restart pulseaudio
Observed result: The device automatically reconnects, sets the volume to 100%
and plays audio. pavucontrol displays the sink volume as 30% even though the
device plays at 100%. Moving the volume slider a bit corrects the volume again.
Desired result: When restarting pulseaudio the sink volume is automatically set
to the configured value and propagated to the output device.
--