I have tried that. PA daemon will crash if new rate is too much different from 
base rate. I guess re-sampler can not tolerate and is not designed for bigger 
rate adjustment.

- Xiaodong 

-----Original Message-----
From: pulseaudio-discuss-bounces+xisun=qca.qualcomm....@lists.freedesktop.org 
[mailto:pulseaudio-discuss-bounces+xisun=qca.qualcomm....@lists.freedesktop.org]
 On Behalf Of Ansis Malinš
Sent: Saturday, October 27, 2012 2:38 AM
To: General PulseAudio Discussion
Subject: Re: [pulseaudio-discuss] a question about audio synchronization 
between local sink and tunnel sink

Excuse me, but why not just remove the "samples rates too different"
limit in the combine sink? Just let it play distorted audio for a few seconds 
until it syncs up. That would solve the problem, wouldn't it?
_______________________________________________
pulseaudio-discuss mailing list
[email protected]
http://lists.freedesktop.org/mailman/listinfo/pulseaudio-discuss
_______________________________________________
pulseaudio-discuss mailing list
[email protected]
http://lists.freedesktop.org/mailman/listinfo/pulseaudio-discuss