otherwise it'll produce a whole lot of checksum errors

and while this would be nice as a storage feature check,
it's hard to be 100% accurate there anyway since a directory
storage can point anywhere, like for instance a btrfs
directory, causing the same issue...

Signed-off-by: Wolfgang Bumiller <w.bumil...@proxmox.com>
---
 PVE/QemuServer.pm | 7 ++++---
 1 file changed, 4 insertions(+), 3 deletions(-)

diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm
index 25282b7..8af4176 100644
--- a/PVE/QemuServer.pm
+++ b/PVE/QemuServer.pm
@@ -1530,14 +1530,15 @@ sub print_drive_commandline_full {
     my $format = $drive->{format};
     my $drive_id = get_drive_id($drive);
 
+    my ($storeid, $volname) = PVE::Storage::parse_volume_id($volid, 1);
+    my $scfg = $storeid ? PVE::Storage::storage_config($storecfg, $storeid) : 
undef;
+
     if (drive_is_cdrom($drive)) {
        $path = get_iso_path($storecfg, $vmid, $volid);
         die "$drive_id: cannot back cdrom drive with PBS snapshot\n" if 
$pbs_name;
     } else {
-       my ($storeid, $volname) = PVE::Storage::parse_volume_id($volid, 1);
        if ($storeid) {
            $path = PVE::Storage::path($storecfg, $volid);
-           my $scfg = PVE::Storage::storage_config($storecfg, $storeid);
            $format //= qemu_img_format($scfg, $volname);
        } else {
            $path = $volid;
@@ -1594,7 +1595,7 @@ sub print_drive_commandline_full {
 
     if (my $cache = $drive->{cache}) {
        $cache_direct = $cache =~ /^(?:off|none|directsync)$/;
-    } elsif (!drive_is_cdrom($drive)) {
+    } elsif (!drive_is_cdrom($drive) && !($scfg && $scfg->{type} eq 'btrfs' && 
!$scfg->{nocow})) {
        $opts .= ",cache=none";
        $cache_direct = 1;
     }
-- 
2.30.2



_______________________________________________
pve-devel mailing list
pve-devel@lists.proxmox.com
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel