when having selected 'off', the next start of the window has both
radiobuttons selected and no change is possible anymore. It seems that
the 'checked: true' triggers only after the 'init' function.

So instead remove the 'checked: true', and add the default in the init
function.

Signed-off-by: Dominik Csapak <d.csa...@proxmox.com>
---
 www/manager6/window/Settings.js | 7 ++-----
 1 file changed, 2 insertions(+), 5 deletions(-)

diff --git a/www/manager6/window/Settings.js b/www/manager6/window/Settings.js
index 4aa7137c..b151adcd 100644
--- a/www/manager6/window/Settings.js
+++ b/www/manager6/window/Settings.js
@@ -34,10 +34,8 @@ Ext.define('PVE.window.Settings', {
 
            var username = sp.get('login-username') || Proxmox.Utils.noneText;
            
me.lookupReference('savedUserName').setValue(Ext.String.htmlEncode(username));
-           var vncMode = sp.get('novnc-scaling');
-           if (vncMode !== undefined) {
-               me.lookupReference('noVNCScalingGroup').setValue({ 
noVNCScalingField: vncMode });
-           }
+           var vncMode = sp.get('novnc-scaling') || 'scale';
+           me.lookupReference('noVNCScalingGroup').setValue({ 
noVNCScalingField: vncMode });
 
            let summarycolumns = sp.get('summarycolumns', 'auto');
            me.lookup('summarycolumns').setValue(summarycolumns);
@@ -379,7 +377,6 @@ Ext.define('PVE.window.Settings', {
                                name: 'noVNCScalingField',
                                inputValue: 'scale',
                                boxLabel: 'Local Scaling',
-                               checked: true,
                            }, {
                                xtype: 'radiofield',
                                name: 'noVNCScalingField',
-- 
2.30.2



_______________________________________________
pve-devel mailing list
pve-devel@lists.proxmox.com
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel

Reply via email to