On 11/11/22 09:36, DERUMIER, Alexandre wrote:
Le mercredi 09 novembre 2022 à 15:19 +0100, Mira Limbeck a écrit :

Why not add the bridge in the pve-bridge script as well? This way
there
would be no need for patch 2 for qemu-server since we always add the
MAC
address to the FDB whenever the tap device is plugged.

If we then remove it in the pve-bridgedown script, there should be no
need for patch 3, right?


ok, I review the whole patch serie, the current behaviour is good.
(Seem the workflow I have send in my previous comment on patch3)


We can't add fdb entry inconditionally in pve-bridge,as on live
migration, we don't want to add fdb entry until the migration is
finished.

(If we do that, the others vms on the target host, will not be able to
communicate with source vms during the migration)

Wouldn't it still send the traffic to the source VM while the entry is still alive?

But since you're a lot more knowledgeable about networks, I trust your judgement in this case.


In this case consider the 3 qemu-server patches:

Reviewed-by: Mira Limbeck <m.limb...@proxmox.com>

Tested-by: Mira Limbeck <m.limb...@proxmox.com>


The pve-network patch has only been tested without SDN for now, I'll try to set something up to test it with SDN as well.

The pve-container patch is on my todo list as well.