>>I recall from ceph list that there were some barrier problems in kernels < 
>>2.6.33 . I don't know whether those are fixed in the kernel from RHEL6 
>>Proxmox uses... 

About barrier, 
they are multiple layers (fs, lvm,md, virtio-blk,...) where it was buggy.
It should be ok with any kernel > 2.6.37  (when barrier have be removed and 
replaced with true FUA implementation)

a good article here:
http://monolight.cc/2011/06/barriers-caches-filesystems/


They are also a bug in old windows virtio-blk driver, fixed 6-7month ago (don't 
remember the version exactly)




----- Mail original -----
De: "Eneko Lacunza" <elacu...@binovo.es>
À: "pve-devel" <pve-devel@pve.proxmox.com>
Envoyé: Jeudi 28 Mai 2015 09:35:26
Objet: Re: [pve-devel] Default cache mode for VM hard drives

Hi Stanislav, 

I really think you should have a look where the problem is. This is not Proxmox 
specific at all, so this list doesn't seem the place to diagnose it. 

If DRBD guys think it's an upper layer problem, maybe they can point you to the 
problematic layer, and then contact the mantainer (probably someone in kernel 
development). 

I recall from ceph list that there were some barrier problems in kernels < 
2.6.33 . I don't know whether those are fixed in the kernel from RHEL6 Proxmox 
uses... 

Cheers 
Eneko 

On 28/05/15 09:22, Stanislav German-Evtushenko wrote: 



Hi Dietmar, 

I did it couple of times already and everytime I had the same answer "upper 
layer problem". Well, as we've done this long way up to this point I would like 
to continue. 

I have just done the same test with mdadm and not DRBD. And what I found that 
this problem was reproducible on the software raid too, just as it was claimed 
by Lars Ellenberg. It means that problem is not only related to DRBD but to 
O_DIRECT mode generally when we don't use host cache and a block device reads 
data directly from userspace. 

The testcase is bellow. 

1. Prepare 

dd if=/dev/zero of=/tmp/mdadm1 bs=1M count=100 
dd if=/dev/zero of=/tmp/mdadm2 bs=1M count=100 
losetup /dev/loop1 /tmp/mdadm1 
losetup /dev/loop2 /tmp/mdadm2 
mdadm --create /dev/md0 --level=1 --raid-devices=2 /dev/loop{1,2} 

2. Write data with O_DIRECT 

./a.out /dev/md0 

3. Check consistency with vbindiff 

vbindiff /tmp/mdadm{1,2} #press enter multiple times to skip metadata 

And here we find that data on "physical devices" is different and md raid did 
not catch this. 


On Thu, May 28, 2015 at 7:40 AM, Dietmar Maurer < diet...@proxmox.com > wrote: 

BQ_BEGIN
> What this means? 

I still think you should discuss that on the DRBD list. 





Best regards, 
Stanislav German-Evtushenko 


_______________________________________________
pve-devel mailing list pve-devel@pve.proxmox.com 
http://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-devel 

BQ_END


-- 
Zuzendari Teknikoa / Director Técnico
Binovo IT Human Project, S.L.
Telf. 943575997
      943493611
Astigarraga bidea 2, planta 6 dcha., ofi. 3-2; 20180 Oiartzun (Gipuzkoa) 
www.binovo.es 

_______________________________________________ 
pve-devel mailing list 
pve-devel@pve.proxmox.com 
http://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-devel 
_______________________________________________
pve-devel mailing list
pve-devel@pve.proxmox.com
http://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-devel

Reply via email to