Thank you for bringing this to our attention. I did a test on a freshly installed PVE 7 + Octopus cluster and there the `bluestore_fsck_quick_fix_on_mount` was set to true... That's why I updated the upgrade guide [0]. Checking the setting before upgrading and if true, setting it to false, should be okay IIUC.
Once we release a version with a fix we will update the guide again to reflect the new situation. Thanks! Aaron [0] https://pve.proxmox.com/wiki/Ceph_Octopus_to_Pacific On 10/28/21 18:19, Eneko Lacunza wrote:
Hi, Regarding this important issue reported for Ceph (just cross-forwarding for those Ceph users not in ceph-user list): 1. Proxmox upgrade wiki page https://pve.proxmox.com/wiki/Ceph_Octopus_to_Pacific marks as optional disabling the conversion with "ceph config set osd bluestore_fsck_quick_fix_on_mount false", and urges to convert ASAP. It is now advised not to perform the conversion until a fix is released. 2. We have upgraded 2 clusters, but both have bluestore_fsck_quick_fix_on_mount set to false. No command setting that flag in our server's history, so I don't think we set that (I wasn't the admin performin the upgrade, I'll be able to check with her tomorrow) 3. Is it possible that for ceph 16.2.6 bluestore_fsck_quick_fix_on_mount default value is false? I expect an emergency fix released soon but I guess checking won't hurt anyone ;) Thanks Eneko EnekoLacunza CTO | Zuzendari teknikoa Binovo IT Human Project 943 569 206 <tel:943 569 206> [email protected] <mailto:[email protected]> binovo.es <//binovo.es> Astigarragako Bidea, 2 - 2 izda. Oficina 10-11, 20180 Oiartzun youtube <https://www.youtube.com/user/CANALBINOVO/> linkedin <https://www.linkedin.com/company/37269706/>
_______________________________________________ pve-user mailing list [email protected] https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-user