Le 28/12/2022 à 12:19, Óscar de Arriba a écrit :
I think Proxmox UI is showing the % of wearout consumed.
In my case, with Dell servers, the UI in fact is not showing anything (N/A), when the Raid storage volume is managed by the raid controller. In this case, I use Dell OMSA (Open Manage Server Administration), to display the values.
But I have another cluster with Ceph, and indeed, it displays 0% as wearout. So I think you are right.
I saw that they are Crucial SATA SSD directly attached on the motherboard. What kind of filesystem do you have on these SSDs ? Can you run pveperf on /dev/mapper/pveroot to see what are the performances ?
Alain -- Administrateur Système/Réseau C2N Centre de Nanosciences et Nanotechnologies (UMR 9001) Boulevard Thomas Gobert (ex Avenue de La Vauve), 91120 Palaiseau Tel : 01-70-27-06-88 Bureau A255 _______________________________________________ pve-user mailing list [email protected] https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-user