Mandi! Eneko Lacunza via pve-user
  In chel di` si favelave...

> What disk model?

        HGST HUS726T4TAL


> sdc has only one backing HDD right?

Yes, it is called 'NonRAID' in newer PERC lingo; seems a RAID0 configuration
but with some more 'insight'...


> 84 IOPS is not much, but I don't think you can get much more from an HDD 
> with random RW...
> PERC controller is quite new, maybe driver in PVE 7 is more optimized...

Uh, oh... never minded about that.

There's some way to at least test PVE7 kernel with PVE6?

-- 
  chi si convertiva nel novanta
  ne era dispensato nel novantuno                       (F. De Andre`)



_______________________________________________
pve-user mailing list
[email protected]
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-user