STINNER Victor added the comment:

I opened the issue #23570: Change "with subprocess.Popen():" (context manager) 
to ignore broken pipe error.

> FAIL: test_broken_pipe_cleanup (test.test_subprocess.ContextManagerTests)

Serhiy: see existing test_communicate_epipe() and 
test_communicate_epipe_only_stdin() tests which are now reliable and portable.

You should write more data (2**20 bytes) and set the buffer size to a value 
larger than the input data, to buffer all data, so the write occurs at 
stdin.close() in Popen.__exit__().

By the way, instead of an hardcoded value (2**20), support.PIPE_MAX_SIZE may be 
more appropriate.

----------

_______________________________________
Python tracker <rep...@bugs.python.org>
<http://bugs.python.org/issue21619>
_______________________________________
_______________________________________________