Glenn Linderman <v+pyt...@g.nevcal.com> added the comment:

Pierre said:
In all cases the interpreter must be launched with the -u option. As stated in 
the documentation, the effect of this option is to "force the binary layer of 
the stdin, stdout and stderr streams (which is available as their buffer 
attribute) to be unbuffered. The text I/O layer will still be line-buffered.". 
On my PC (Windows XP) this is required to be able to read all the data stream ; 
otherwise, only the beginning is read. I tried Glenn's suggestion with mscvrt, 
with no effect

I say:
If you start the interpreter with -u, then my mscvrt has no effect.  Without 
it, there is an effect.  Read on...

Antoine said:
Could you open a separate bug with a simple piece of code to reproduce
the issue (preferably without launching an HTTP server :))?

I say:
issue 10841

----------

_______________________________________
Python tracker <rep...@bugs.python.org>
<http://bugs.python.org/issue4953>
_______________________________________