When a guest sets MaxPacketSize to 0 in an OHCI Endpoint Descriptor, ohci_service_td() transfers 0 bytes per iteration. The Transfer Descriptor never completes because CBP never advances toward BE, causing ohci_service_ed_list() to loop indefinitely and hang QEMU.
Add a check for MPS==0 after extracting the field from ED flags. If MPS is zero, call ohci_die() to reset the controller and return an error, preventing the infinite loop. Fixes: CVE-2026-3890 Reported-by: Jenny Guanni Qu <[email protected]> Signed-off-by: Jenny Guanni Qu <[email protected]> --- hw/usb/hcd-ohci.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/hw/usb/hcd-ohci.c b/hw/usb/hcd-ohci.c index 1aeed9286f..b93a99593e 100644 --- a/hw/usb/hcd-ohci.c +++ b/hw/usb/hcd-ohci.c @@ -956,6 +956,10 @@ static int ohci_service_td(OHCIState *ohci, struct ohci_ed *ed) if (len && dir != OHCI_TD_DIR_IN) { /* The endpoint may not allow us to transfer it all now */ pktlen = (ed->flags & OHCI_ED_MPS_MASK) >> OHCI_ED_MPS_SHIFT; + if (pktlen == 0) { + ohci_die(ohci); + return 1; + } if (pktlen > len) { pktlen = len; } -- 2.34.1