On 6/26/26 11:05, Ziyi Fu wrote:
From: Ziyi Fu <[email protected]>
Record the completion side of parameter-based control transfers when they
complete asynchronously. This lets pcap captures include descriptor
response data for requests such as GET_DESCRIPTOR from usb-host devices.
The synchronous path already recorded the completion, but the async
SETUP_STATE_PARAM path was missing it.
Signed-off-by: Ziyi Fu <[email protected]>
Fixes: 0f6dba145a4b ("usb: add pcap support.")
Applied to the trivial-patches tree.
Thanks!