The FCR write handler cleared bit 1 of the status register (sr) instead
of the SH_SERIAL_FLAG_RDF flag in the flags field. This meant the
"receive data full" condition was never actually cleared when the guest
reset the FIFO.

Reported-by: Pavee Hui <[email protected]>
Fixes: 63242a007a18 ("SH4: Serial controller improvement")
Signed-off-by: Marc-André Lureau <[email protected]>
---
 hw/char/sh_serial.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/hw/char/sh_serial.c b/hw/char/sh_serial.c
index 10f96e3a44bc..30a22ea2d1c0 100644
--- a/hw/char/sh_serial.c
+++ b/hw/char/sh_serial.c
@@ -175,7 +175,7 @@ static void sh_serial_write(void *opaque, hwaddr offs,
             }
             if (val & (1 << 1)) {
                 sh_serial_clear_fifo(s);
-                s->sr &= ~(1 << 1);
+                s->flags &= ~SH_SERIAL_FLAG_RDF;
             }
 
             return;

-- 
2.56.0.rc0.29.g47ce80527c56