From: Junjie Cao <[email protected]> Hi Jamin,
On v6, the local test device delivers data after an IOERROR without another start request. STALL stops the stream. With a bulk IN endpoint at 0x83, v6 accepts the start request and sends the data as an interrupt_packet after the device wakes. Could we also reject non-interrupt endpoints in start_interrupt_receiving()? Thanks, Junjie