On Mon, Mar 17, 2014 at 04:52:59PM +0100, Christian Borntraeger wrote: > This causes the following bug during managedsave of s390 with a guest that > has multiple disks with dataplane. > > (gdb) bt > #0 object_deinit (type=0x0, obj=0x807e8750) at > /home/cborntra/REPOS/qemu/qom/object.c:410 > #1 object_finalize (data=0x807e8750) at > /home/cborntra/REPOS/qemu/qom/object.c:424 > #2 object_unref (obj=0x807e8750) at > /home/cborntra/REPOS/qemu/qom/object.c:726 > #3 0x000000008011da60 in object_property_del (obj=0x807e8d80, > name=0x807e8d60 "virtio-blk", errp=<optimized out>) at > /home/cborntra/REPOS/qemu/qom/object.c:783 > #4 0x000000008011dc0e in object_property_del_child (errp=0x0, > child=0x807e8750, obj=0x807e8d80) at > /home/cborntra/REPOS/qemu/qom/object.c:386 > #5 object_unparent (obj=0x807e8750) at > /home/cborntra/REPOS/qemu/qom/object.c:403 > #6 0x0000000080183898 in virtio_blk_data_plane_destroy (s=0x8088a750) at > /home/cborntra/REPOS/qemu/hw/block/dataplane/virtio-blk.c:430
Are you able to reproduce this reliably? 198fd05c357afff22f0b0e02639937519ed49b1f should have fixed it. Stefan