On Mon, Mar 17, 2014 at 04:52:59PM +0100, Christian Borntraeger wrote:
> This causes the following bug during managedsave of s390 with a guest that 
> has multiple disks with dataplane.
> 
> (gdb) bt
> #0  object_deinit (type=0x0, obj=0x807e8750) at 
> /home/cborntra/REPOS/qemu/qom/object.c:410
> #1  object_finalize (data=0x807e8750) at 
> /home/cborntra/REPOS/qemu/qom/object.c:424
> #2  object_unref (obj=0x807e8750) at 
> /home/cborntra/REPOS/qemu/qom/object.c:726
> #3  0x000000008011da60 in object_property_del (obj=0x807e8d80, 
> name=0x807e8d60 "virtio-blk", errp=<optimized out>) at 
> /home/cborntra/REPOS/qemu/qom/object.c:783
> #4  0x000000008011dc0e in object_property_del_child (errp=0x0, 
> child=0x807e8750, obj=0x807e8d80) at 
> /home/cborntra/REPOS/qemu/qom/object.c:386
> #5  object_unparent (obj=0x807e8750) at 
> /home/cborntra/REPOS/qemu/qom/object.c:403
> #6  0x0000000080183898 in virtio_blk_data_plane_destroy (s=0x8088a750) at 
> /home/cborntra/REPOS/qemu/hw/block/dataplane/virtio-blk.c:430

Are you able to reproduce this reliably?

198fd05c357afff22f0b0e02639937519ed49b1f should have fixed it.

Stefan

Reply via email to