runtime_exception computes the psw.addr value using the actual exception
address and the instruction length computed by calling the get_ilen
function. However as explained above the get_ilen code, it returns the
actual instruction length, and not the ILC. Therefore there is no need to
multiply the value by 2.

Cc: Alexander Graf <ag...@suse.de>
Cc: Richard Henderson <r...@twiddle.net>
Signed-off-by: Aurelien Jarno <aurel...@aurel32.net>
---
 target-s390x/misc_helper.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/target-s390x/misc_helper.c b/target-s390x/misc_helper.c
index 3ec7268..b375ab7 100644
--- a/target-s390x/misc_helper.c
+++ b/target-s390x/misc_helper.c
@@ -61,7 +61,7 @@ void QEMU_NORETURN runtime_exception(CPUS390XState *env, int 
excp,
     /* Advance past the insn.  */
     t = cpu_ldub_code(env, env->psw.addr);
     env->int_pgm_ilen = t = get_ilen(t);
-    env->psw.addr += 2 * t;
+    env->psw.addr += t;
 
     cpu_loop_exit(cs);
 }
-- 
2.1.4