Delta value must be updated on period/freq change, otherwise running timer would be restarted (counter reloaded with old delta). Only m68k/mcf520x and arm/arm_timer devices are currently doing freq change correctly, i.e. stopping the timer. Perform delta update to fix affected devices and eliminate potential further mistakes.
Signed-off-by: Dmitry Osipenko <dig...@gmail.com> --- hw/core/ptimer.c | 2 ++ 1 file changed, 2 insertions(+) diff --git a/hw/core/ptimer.c b/hw/core/ptimer.c index 96a6c7a..8c2dd9f 100644 --- a/hw/core/ptimer.c +++ b/hw/core/ptimer.c @@ -207,6 +207,7 @@ void ptimer_stop(ptimer_state *s) /* Set counter increment interval in nanoseconds. */ void ptimer_set_period(ptimer_state *s, int64_t period) { + s->delta = ptimer_get_count(s); s->period = period; s->period_frac = 0; if (s->enabled) { @@ -218,6 +219,7 @@ void ptimer_set_period(ptimer_state *s, int64_t period) /* Set counter frequency in Hz. */ void ptimer_set_freq(ptimer_state *s, uint32_t freq) { + s->delta = ptimer_get_count(s); s->period = 1000000000ll / freq; s->period_frac = (1000000000ll << 32) / freq; if (s->enabled) { -- 2.6.4