John Snow <js...@redhat.com> writes:

> Since we're out in a new module, do a quick cursory pass of some of the
> more obvious style issues.
>
> Signed-off-by: John Snow <js...@redhat.com>
> ---
>  python/qemu/machine.py | 23 +++++++++++++++--------
>  1 file changed, 15 insertions(+), 8 deletions(-)
>
> diff --git a/python/qemu/machine.py b/python/qemu/machine.py
> index a8a311b035..925046fc20 100644
> --- a/python/qemu/machine.py
> +++ b/python/qemu/machine.py
> @@ -16,7 +16,6 @@ import errno
>  import logging
>  import os
>  import subprocess
> -import re
>  import shutil
>  import socket
>  import tempfile
> @@ -54,7 +53,7 @@ class MonitorResponseError(qmp.QMPError):
>          self.reply = reply
>  
>  
> -class QEMUMachine(object):
> +class QEMUMachine:

Premature.  Makes it a "classic class" in Python 2.  See

https://docs.python.org/2.7/reference/datamodel.html#new-style-and-classic-classes
https://pythonclock.org/

>      """
>      A QEMU VM
>  
> @@ -119,8 +118,10 @@ class QEMUMachine(object):
>          self.shutdown()
>          return False
>  
> -    # This can be used to add an unused monitor instance.
>      def add_monitor_null(self):
> +        """
> +        This can be used to add an unused monitor instance.
> +        """
>          self._args.append('-monitor')
>          self._args.append('null')
>  
> @@ -143,10 +144,13 @@ class QEMUMachine(object):
>          self._args.append(','.join(options))
>          return self
>  
> -    # Exactly one of fd and file_path must be given.
> -    # (If it is file_path, the helper will open that file and pass its
> -    # own fd)
>      def send_fd_scm(self, fd=None, file_path=None):
> +        """
> +        Send an fd or file_path to socket_scm_helper.
> +
> +        Exactly one of fd and file_path must be given.
> +        If it is file_path, the helper will open that file and pass its own 
> fd.
> +        """
>          # In iotest.py, the qmp should always use unix socket.
>          assert self._qmp.is_scm_available()
>          if self._socket_scm_helper is None:
> @@ -194,14 +198,17 @@ class QEMUMachine(object):
>              raise
>  
>      def is_running(self):
> +        """Returns true if the VM is running."""
>          return self._popen is not None and self._popen.poll() is None
>  
>      def exitcode(self):
> +        """Returns the exit code if possible, or None."""
>          if self._popen is None:
>              return None
>          return self._popen.poll()
>  
>      def get_pid(self):
> +        """Returns the PID of the running process, or None."""
>          if not self.is_running():
>              return None
>          return self._popen.pid
> @@ -339,7 +346,7 @@ class QEMUMachine(object):
>                  command = ' '.join(self._qemu_full_args)
>              else:
>                  command = ''
> -            LOG.warn(msg, -exitcode, command)
> +            LOG.warning(msg, -exitcode, command)

Is this a bug fix?

>  
>          self._launched = False
>  
> @@ -373,7 +380,7 @@ class QEMUMachine(object):
>          """
>          Poll for one queued QMP events and return it
>          """
> -        if len(self._events) > 0:
> +        if self._events:
>              return self._events.pop(0)
>          return self._qmp.pull_event(wait=wait)

Reply via email to