On Thu, 21 Jul 2011 03:27:14 +0200 Alexander Graf <ag...@suse.de> wrote:
> All guest CPUs need to be specified in the device trees. Since removing nodes > is easy with FDT, but adding nodes is not, we just put 32 CPU nodes into the > device tree and remove them later on init when not used. Adding nodes isn't that hard... I'm also hesitant to stick so many CPUs on something modeled after an e500v2-era mpc85xx. E.g. in the MPIC the upper bits of xIDR are used for EP/CIx. The newer MPIC used in p4080 and such move crit/mcheck routing into a separate register. There are similar constraints in guts (power management), and possibly elsewhere. -Scott