In NVMe 1.4, a namespace must report an ID descriptor of UUID type if it doesn't support EUI64 or NGUID. Add a new namespace property, "uuid", that provides the user the option to either specify the UUID explicitly or have a UUID generated automatically every time a namespace is initialized.
Suggested-by: Klaus Jansen <i...@irrelevant.dk> Signed-off-by: Dmitry Fomichev <dmitry.fomic...@wdc.com> Reviewed-by: Klaus Jansen <i...@irrelevant.dk> --- hw/block/nvme-ns.c | 1 + hw/block/nvme-ns.h | 1 + hw/block/nvme.c | 9 +++++---- 3 files changed, 7 insertions(+), 4 deletions(-) diff --git a/hw/block/nvme-ns.c b/hw/block/nvme-ns.c index b69cdaf27e..de735eb9f3 100644 --- a/hw/block/nvme-ns.c +++ b/hw/block/nvme-ns.c @@ -129,6 +129,7 @@ static void nvme_ns_realize(DeviceState *dev, Error **errp) static Property nvme_ns_props[] = { DEFINE_BLOCK_PROPERTIES(NvmeNamespace, blkconf), DEFINE_PROP_UINT32("nsid", NvmeNamespace, params.nsid, 0), + DEFINE_PROP_UUID("uuid", NvmeNamespace, params.uuid), DEFINE_PROP_END_OF_LIST(), }; diff --git a/hw/block/nvme-ns.h b/hw/block/nvme-ns.h index ea8c2f785d..a38071884a 100644 --- a/hw/block/nvme-ns.h +++ b/hw/block/nvme-ns.h @@ -21,6 +21,7 @@ typedef struct NvmeNamespaceParams { uint32_t nsid; + QemuUUID uuid; } NvmeNamespaceParams; typedef struct NvmeNamespace { diff --git a/hw/block/nvme.c b/hw/block/nvme.c index 5a9493d89f..29139d8a17 100644 --- a/hw/block/nvme.c +++ b/hw/block/nvme.c @@ -1574,6 +1574,7 @@ static uint16_t nvme_identify_nslist(NvmeCtrl *n, NvmeRequest *req) static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req) { + NvmeNamespace *ns; NvmeIdentify *c = (NvmeIdentify *)&req->cmd; uint32_t nsid = le32_to_cpu(c->nsid); uint8_t list[NVME_IDENTIFY_DATA_SIZE]; @@ -1593,7 +1594,8 @@ static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req) return NVME_INVALID_NSID | NVME_DNR; } - if (unlikely(!nvme_ns(n, nsid))) { + ns = nvme_ns(n, nsid); + if (unlikely(!ns)) { return NVME_INVALID_FIELD | NVME_DNR; } @@ -1602,12 +1604,11 @@ static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req) /* * Because the NGUID and EUI64 fields are 0 in the Identify Namespace data * structure, a Namespace UUID (nidt = 0x3) must be reported in the - * Namespace Identification Descriptor. Add a very basic Namespace UUID - * here. + * Namespace Identification Descriptor. Add the namespace UUID here. */ ns_descrs->uuid.hdr.nidt = NVME_NIDT_UUID; ns_descrs->uuid.hdr.nidl = NVME_NIDT_UUID_LEN; - stl_be_p(&ns_descrs->uuid.v, nsid); + memcpy(&ns_descrs->uuid.v, ns->params.uuid.data, NVME_NIDT_UUID_LEN); return nvme_dma(n, list, NVME_IDENTIFY_DATA_SIZE, DMA_DIRECTION_FROM_DEVICE, req); -- 2.21.0