On 11/8/21 12:02, Janosch Frank wrote:
> On 11/5/21 23:46, Collin Walling wrote:
>> The CPNC portion of the diag 318 data is erroneously reset during an
>> initial CPU reset caused by SIGP. Let's go ahead and relocate the
>> diag318_info field within the CPUS390XState struct such that it is
>> only zeroed during a clear reset. This way, the CPNC will be retained
>> for each VCPU in the configuration after the diag 318 instruction
>> has been invoked by the kernel.
>>
>> Additionally, the diag 318 data reset is handled via the CPU reset
>> code. The set_diag318 code can be merged into the handler function
>> and the helper functions can consequently be removed.
>>
>> Signed-off-by: Collin Walling <wall...@linux.ibm.com>
> 
> Fixes tag?
> 

Will include this on v2 post. Thank you.

[...]

-- 
Regards,
Collin

Stay safe and stay healthy

Reply via email to