On 11/8/21 12:02, Janosch Frank wrote: > On 11/5/21 23:46, Collin Walling wrote: >> The CPNC portion of the diag 318 data is erroneously reset during an >> initial CPU reset caused by SIGP. Let's go ahead and relocate the >> diag318_info field within the CPUS390XState struct such that it is >> only zeroed during a clear reset. This way, the CPNC will be retained >> for each VCPU in the configuration after the diag 318 instruction >> has been invoked by the kernel. >> >> Additionally, the diag 318 data reset is handled via the CPU reset >> code. The set_diag318 code can be merged into the handler function >> and the helper functions can consequently be removed. >> >> Signed-off-by: Collin Walling <wall...@linux.ibm.com> > > Fixes tag? >
Will include this on v2 post. Thank you. [...] -- Regards, Collin Stay safe and stay healthy