From: Marc-André Lureau <marcandre.lur...@redhat.com>

The D-Bus connection starts processing messages before QEMU has the time
to set the object manager server. This is causing dbus-display-test to
fail randomly with:

ERROR:../tests/qtest/dbus-display-test.c:68:test_dbus_display_vm:
assertion failed
(qemu_dbus_display1_vm_get_name(QEMU_DBUS_DISPLAY1_VM(vm)) ==
"dbus-test"): (NULL == "dbus-test") ERROR

Use the delayed message processing flag and method to avoid that
situation.

(the bus connection doesn't need a fix, as the initialization is done
synchronously)

Reported-by: Robinson, Cole <crobi...@redhat.com>
Signed-off-by: Marc-André Lureau <marcandre.lur...@redhat.com>
---
 ui/dbus.c | 4 +++-
 1 file changed, 3 insertions(+), 1 deletion(-)

diff --git a/ui/dbus.c b/ui/dbus.c
index 7a87612379e8..70dd4be210e4 100644
--- a/ui/dbus.c
+++ b/ui/dbus.c
@@ -268,6 +268,7 @@ dbus_display_add_client_ready(GObject *source_object,
     }
 
     g_dbus_object_manager_server_set_connection(dbus_display->server, conn);
+    g_dbus_connection_start_message_processing(conn);
 }
 
 
@@ -300,7 +301,8 @@ dbus_display_add_client(int csock, Error **errp)
 
     g_dbus_connection_new(G_IO_STREAM(conn),
                           guid,
-                          G_DBUS_CONNECTION_FLAGS_AUTHENTICATION_SERVER,
+                          G_DBUS_CONNECTION_FLAGS_AUTHENTICATION_SERVER|
+                          G_DBUS_CONNECTION_FLAGS_DELAY_MESSAGE_PROCESSING,
                           NULL,
                           dbus_display->add_client_cancellable,
                           dbus_display_add_client_ready,
-- 
2.36.0.44.g0f828332d5ac