>>> In article <[EMAIL PROTECTED]>, "Joshua Coombs" <[EMAIL PROTECTED]> writes:
>> For some refclocks this make sense (as they may provide timestamps once >> per second), and I believe Dave has done some work on handling this case >> for some refclocks. Joshua> I tried it, and I can't observe any change on the ACTS refclock. I Joshua> still only get one time stamp line logged in clockstats per call. I forget where Dave made this change - it will show up because ntpd will believe the refclock "sooner" (like maybe within a minute) instead of after something like 16 minutes. I forget the details... H _______________________________________________ questions mailing list [email protected] https://lists.ntp.isc.org/mailman/listinfo/questions