Rune Magnussen wrote:
> Hi.
> 
> I am trying to to get my Meinberg DCF77 C51 unit to work. The problem is
> that ntpd does not see any timecodes even though thr unit is synchronised
> to the radiosignal.
> 
> The clock is connected via a modem cable with a null-modem
> adapter. I tried with a serial printer cable as well, but not for long. The
> serial port is detected by the kernel. As described in the docs I made a 
> symlink /dev/refclock-0 to /dev/ttyS0. I guess that /dev/ttyS0 is the right 
> one.
> as the PC only has one serial port on the outside.
> 
> The DCF77 C51 shows up as GENERIC(0) with refid DCFa but the clock is never
> "reached". I have activated clockstats in ntpd, but nothing shows up.

The Meinberg box has a db25 connector? right?

you need:

Meinberg(db25)          PC(db9 female)
SGND    7               SGND    5
TXD     3               RXD     2
RXD     2               TXD     3

i don't know about Handshake signals
There used to be Mouse Adapters DB25 mouse to DB9 PC

uwe