Lindholm Roger wrote: > Hi, > > I am running NTP 4.2.4 on Windows and am trying to get the NMEA refclock > to work with a Garmin GPSmap76. I am using a serial cable connected to > COM1 at 4800/8/1/N and no flow control. I am receiving what looks like > the correct messages and the debug output don't show anything strange > (as far as I can comprehend). It does however not set the time and it > logs event 'clk_fault' (0x03). The debug output shows the following for > each NMEA record received: >
[too much snipping] > refclock_gtraw: fd 1808 time 3385723813.932521 timecode 126 > $GPRMC,145812,V,5938.5864,N,01706.8010,E,0.0,0.0,160407,3.6,E,S*15 > > $GPRMB,V,,,,,,,,,,,,A,S*0E > > $GPGGA,145812,5938.5864,N,0170 Your GPRMC sentence is reporting that you do not have a valid position, and your GPGGA sentence is invalid. Make sure that the GPS is gathering valid position fixes so it will output data that the NMEA driver can use. Michael _______________________________________________ questions mailing list [email protected] https://lists.ntp.isc.org/mailman/listinfo/questions