David Woolley wrote: > Richard B. Gilbert wrote: > >> >> A very poor configuration if accuracy is wanted. Typically, one >> "edge", leading or trailing, of the PPS output is within 50 to 100 >> nanoseconds of the "top of the second"! The serial output tells you >> the time value of the PPS "edge". > > As I read it, the PPS was a red herring. I think the appliances are > ethernet appliances, so any notional serial link from the reference > clock is purely internal. The appliances probably do use PPS. The appliance does indeed have a high-quality receiver, and has NTP on Ethernet output, as well as PPS (DE-9 connector) and 10Mhz on BNC (coax) connector.
Jason. _______________________________________________ questions mailing list [email protected] https://lists.ntp.org/mailman/listinfo/questions