David Taylor wrote:
On 30/10/2012 17:57, David Woolley wrote:
Thanks, David. Do you think that it would still be 20 minutes when the clock in question is being polled every 16 seconds?
The starting point, without using tinker stepout, is 15 minutes. To that you have to add the time to get a best sample with the new time, and, possibly, the time to reload the sample FIFO.
This is certainly the case for external sources. I think it is true for reference clocks.
_______________________________________________ questions mailing list questions@lists.ntp.org http://lists.ntp.org/listinfo/questions