Hello Eric -

On Tuesday 09 January 2001 05:53, Eric Elliston wrote:
> Can anyone tell me how to fix this...
>
> Mon Jan  8 13:52:16 2001: ERR: Attribute number 121 (vendor ) is not
> defined in
> your dictionary
>
> I get these over and over.   We use Platypus (ODBC) to connect to the
> User Database....
>

What dictionary are you using? 

This definition is from the standard Radiator dictionary (which you can just 
cut and paste into whatever dictionary you are using).

ATTRIBUTE       Ascend-Modem-SlotNo             121     integer    

hth

Hugh

-- 
Radiator: the most portable, flexible and configurable RADIUS server 
anywhere. Available on *NIX, *BSD, Windows 95/98/2000, NT, MacOS X.
-
Nets: internetwork inventory and management - graphical, extensible,
flexible with hardware, software, platform and database independence.

===
Archive at http://www.starport.net/~radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.

Reply via email to