I use a SIMLOGIN field in MySQL in conjunction with the Session Database in Radiator to handle this. I only allow 1 login at a time per username unless the customer is paying for more than one computer to connect at a time. If someone calls and can't log in, the Radiator logs will show that they were denied for the reason of Simultaneous logins exceeded. You can then have the customer change their password and/or check your accounting logs if you have it setup to log the Calling-Station-ID attribute to see where the other call is coming from.
-Ronan -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of User BALGAA System Engineer Sent: Monday, 28 January, 2002 05:16 To: Hugh Irvine Cc: [EMAIL PROTECTED] Subject: (RADIATOR) Radius packet or server attack protection. Hugh, Some of our dial-up users complain about someone using they username and password. How can I to secure and protect from such attacks and hacking? Now Radiator AAA server (2.19) and NAS's (AS5300,AS5400,Ascend MAX 4060) same subnet. Thanks, Balgaa === Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL PROTECTED] To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message. === Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL PROTECTED] To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.