Hi !

We are using Radiator 2.19 with Nortels BSN Shatsa 5000.

Sometimes we miss a stoprecord or something happens with the BSN, the user 
tries to reconnect, but the user is still in the RADONLINE database.

How can we solve this ? Are there any timeouts or something ?


<SessionDatabase SQL>
          Identifier      SQLSDB
          DBSource        dbi:mysql:radius:localhost
          DBUsername      xxxxxxxx
          DBAuth          xxxxxxx
</SessionDatabase>

Cheers

/andreas


===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.