Hello Sergio -
Please have a look at section 16 in the Radiator 3.5 reference manual ("doc/ref.html").
regards
Hugh
On Tuesday, Mar 11, 2003, at 05:32 Australia/Melbourne, Sergio Robles wrote:
Hi Everyone,
We are currently evaluating Radiator.
Some form exists to reload the radiator configuration, without having to make stop/start complete of the service. I create that is something related with send the signal "SIGHUP" to the service.
Exists some way to automate it? (config file... or manual entry on cron/schedule)
As utility of the system those signals can be sent... kill.exe?From where i can download (microsoft, cygwin...)?
We would appreciate some help. Thanks.
Robles
=== Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL PROTECTED] To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.
NB: have you included a copy of your configuration file (no secrets), together with a trace 4 debug showing what is happening?
-- Radiator: the most portable, flexible and configurable RADIUS server anywhere. Available on *NIX, *BSD, Windows 95/98/2000, NT, MacOS X. - Nets: internetwork inventory and management - graphical, extensible, flexible with hardware, software, platform and database independence.
=== Archive at http://www.open.com.au/archives/radiator/ Announcements on [EMAIL PROTECTED] To unsubscribe, email '[EMAIL PROTECTED]' with 'unsubscribe radiator' in the body of the message.