Hi all,

I am testing authentication in a WLAN with Windows XP (SP1) client and
somehow have trouble to make it work.

My set-up:

Access point: Intel PRO/Wireless 5000 
Client: Win XP with Service Pack 1 installed
Radiator with the eap_peap.cfg file from  /goodies 
Certificates on the cleint and server are installed 

The log file says:

** Received from 193.175.134.99 port 1024 ....
Code:       Access-Request
Identifier: 184
Authentic:  4*1pT<18>]<141>P<128><29>eJ<154>><255>
Attributes:
        User-Name = "mikem"
        NAS-IP-Address = 193.175.134.99
        Called-Station-Id = "00053C072C2E"
        Calling-Station-Id = "00053C05FA57"
        NAS-Identifier = "IAP2"
        NAS-Port = 1
        Framed-MTU = 1400
        NAS-Port-Type = Wireless-IEEE-802-11
        EAP-Message = <2><183><0><10><1>mikem
        Message-Authenticator =
<199><1>[-+,<182>k<131><153><204>K<232><31>c<130>

Thu Jun 19 18:38:41 2003: DEBUG: Handling request with Handler ''
Thu Jun 19 18:38:41 2003: DEBUG:  Deleting session for mikem,
193.175.134.99, 1
Thu Jun 19 18:38:41 2003: DEBUG: Handling with Radius::AuthFILE: 
Thu Jun 19 18:38:41 2003: DEBUG: Handling with EAP: code 2, 183, 10
Thu Jun 19 18:38:41 2003: DEBUG: Response type 1
Thu Jun 19 18:38:41 2003: ERR: Could not handle an EAP request: Can't
locate object method "response_identity" via package "Radius::EAP_25"
(perhaps you forgot to load "Radius::EAP_25"?) at
/usr/lib/perl5/site_perl/5.6.1/Radius/EAP.pm line 139.

Thu Jun 19 18:38:41 2003: INFO: Access rejected for mikem: Could not
handle an EAP request
Thu Jun 19 18:38:41 2003: DEBUG: Packet dump:
*** Sending to 193.175.134.99 port 1024 ....
Code:       Access-Reject
Identifier: 184
Authentic:  4*1pT<18>]<141>P<128><29>eJ<154>><255>
Attributes:
        Reply-Message = "Request Denied"

Thu Jun 19 18:38:41 2003: WARNING: Malformed request packet: Attribute 0
with length 0: ignored
Thu Jun 19 18:38:41 2003: DEBUG: Packet dump:


How do I load the PERL module or am I just using the wrong user (mikem)
?

Any help would be appreciated.

Thanks.
-- 
------------------------------------------------------------------------------------
Peter Weik
    
Fraunhofer Institut FOKUS       phone:  + 49-30 3463-7151
Kaiserin-Augusta-Allee 31       
D-10589 Berlin                  e-mail: [EMAIL PROTECTED]  
------------------------------------------------------------------------------------

===
Archive at http://www.open.com.au/archives/radiator/
Announcements on [EMAIL PROTECTED]
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.