On 05/10/2012 09:48 AM, Jens Neu wrote: > unfortunately the error is in my email only, i typed this from my config > file and did not copy/paste. I'll be a little bit more verbose, here's my > current handler config, just stripped for some AcctColumnDefs. I Tried the > "AcctLogFileName %L/detail.local-testing" on various positions. The > current one is just based on my common sense. Effect is silence, no error > in the log or something (Trace is 4). "Filename %L/authlog.local-testing" > works as expected.
Hmm, I took your configuration I tried it on a machine that even does not have Oracle stuff installed. The SQL insert of course failed, but detail.loca-testing was created with the accounting record. So for me it worked as expected. Are you sure you are not handling accounting with some other Handler (or possibly Realm)? Heikki > <Handler Client-Identifier=local-testing> > > AcctLogFileName %L/detail.local-testing > > <AuthLog SQL> > DBSource > dbi:Oracle:host=db.host.example.com;service_name=radiator > DBUsername radiator > DBAuth radiator > Table RADAUTHLOG > LogSuccess 1 > SuccessQuery insert into RADAUTHLOG (TIME_STAMP, USERNAME, > TYPE) values (%t, '%n', 1) > LogFailure 1 > FailureQuery insert into RADAUTHLOG (TIME_STAMP, USERNAME, > TYPE, REASON) values (%t, '%n', 0, %1) > </AuthLog> > > <AuthLog FILE> > > Identifier filelogger_local-testing > Filename %L/authlog.local-testing > > LogSuccess 1 > LogFailure 1 > </AuthLog> > > AuthByPolicy ContinueWhileAccept > > <AuthBy GROUP> > AuthByPolicy ContinueWhileAccept > <AuthBy SQL> > > DBSource > dbi:Oracle:host=db.host.example.com;service_name=radiator > DBUsername radiator > DBAuth radiator > > AuthSelect select PASSWORD from DEVICE where > USER_NAME=%0 > > AccountingTable ACCOUNTING > AcctColumnDef USERNAME,User-Name > [...] > AcctColumnDef FRAMEDIPADDRESS,Framed-IP-Address > > AcctFailedLogFileName %D/missedaccounting > SQLRecoveryFile %D/missedaccounting > </AuthBy> > > <AuthBy DYNADDRESS> > > AddressAllocator allocator.pool1 > PoolHint pool1 > </AuthBy> > </AuthBy> > </Handler> > > > www.biotronik.com > > BIOTRONIK SE & Co. KG > Woermannkehre 1, 12359 Berlin, Germany > Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 > > Vertreten durch ihre Komplementärin: > BIOTRONIK MT SE > Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B > Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. > Lothar Krings, Dr. Torsten Wolf > > BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management > systems and Vascular Intervention devices. Quality, innovation, and > reliability define BIOTRONIK and our growing success. We are innovators of > technologies like the first wireless remote monitoring system - Home > Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as > state-of-the-art stents, balloons and guide wires for coronary and > peripheral indications. We highly invest in the development of drug > eluting devices and are leading the industry with our drug eluting > absorbable metal scaffold program. > > This e-mail and the information it contains including attachments are > confidential and meant only for use by the intended recipient(s); > disclosure or copying is strictly prohibited. If you are not addressed, > but in the possession of this e-mail, please notify the sender immediately > and delete the document. > > > > www.biotronik.com > > BIOTRONIK SE & Co. KG > Woermannkehre 1, 12359 Berlin, Germany > Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRA 6501 > > Vertreten durch ihre Komplementärin: > BIOTRONIK MT SE > Sitz der Gesellschaft: Berlin, Registergericht: Berlin HRB 118866 B > Geschäftsführende Direktoren: Christoph Böhmer, Dr. Werner Braun, Dr. > Lothar Krings, Dr. Torsten Wolf > > BIOTRONIK - A global manufacturer of advanced Cardiac Rhythm Management > systems and Vascular Intervention devices. Quality, innovation, and > reliability define BIOTRONIK and our growing success. We are innovators of > technologies like the first wireless remote monitoring system - Home > Monitoring®, Closed Loop Stimulation and coveted lead solutions as well as > state-of-the-art stents, balloons and guide wires for coronary and > peripheral indications. We highly invest in the development of drug > eluting devices and are leading the industry with our drug eluting > absorbable metal scaffold program. > > This e-mail and the information it contains including attachments are > confidential and meant only for use by the intended recipient(s); > disclosure or copying is strictly prohibited. If you are not addressed, > but in the possession of this e-mail, please notify the sender immediately > and delete the document. > > _______________________________________________ > radiator mailing list > radiator@open.com.au > http://www.open.com.au/mailman/listinfo/radiator -- Heikki Vatiainen <h...@open.com.au> Radiator: the most portable, flexible and configurable RADIUS server anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald, Platypus, Freeside, TACACS+, PAM, external, Active Directory, EAP, TLS, TTLS, PEAP, TNC, WiMAX, RSA, Vasco, Yubikey, MOTP, HOTP, TOTP, DIAMETER etc. Full source on Unix, Windows, MacOSX, Solaris, VMS, NetWare etc. _______________________________________________ radiator mailing list radiator@open.com.au http://www.open.com.au/mailman/listinfo/radiator